Skip to content
lelon logo

Lelon Electronics Manufacturer Skill

lelon

Lelon Electronics MPN encoding patterns, suffix decoding, and handler guidance. Use when working with Lelon aluminum electrolytic capacitors.

SKILL.md

Full skill instructions

Lelon Electronics Manufacturer Skill

MPN Structure

Lelon MPNs follow this general structure:

[SERIES]-[CAP_CODE][TOLERANCE][VOLTAGE][TR][PACKAGE]
   |         |         |         |      |      |
   |         |         |         |      |      +-- Package code (0605=6.3x5mm)
   |         |         |         |      +-- TR=Tape and Reel
   |         |         |         +-- Voltage code (1C=16V, 1E=25V)
   |         |         +-- Tolerance (M=20%, K=10%, J=5%)
   |         +-- 3-digit capacitance code (101=100uF)
   +-- Series prefix (VE, VR, VZ, REA, REB, REC, OVZ, OVR)

Example Decoding

VE-101M1CTR-0605
|  |  | | |   |
|  |  | | |   +-- Package: 6.3x5mm
|  |  | | +-- TR = Tape and Reel
|  |  | +-- 1C = 16V
|  |  +-- M = +/​-20% tolerance
|  +-- 101 = 100uF (10 x 10^1)
+-- VE = Low Impedance series

REA221M1CTR-0810
|  |  | | |   |
|  |  | | |   +-- Package: 8x10mm
|  |  | | +-- TR = Tape and Reel
|  |  | +-- 1C = 16V
|  |  +-- M = +/​-20% tolerance
|  +-- 221 = 220uF (22 x 10^1)
+-- REA = Radial Lead series (no hyphen after prefix)

Series Reference

V-Series (with hyphen)

SeriesDescriptionApplication
VELow ImpedancePower supply filtering, high ripple current
VRStandardGeneral purpose applications
VZHigh TemperatureAutomotive, harsh environments

RE-Series (radial lead, no hyphen)

SeriesDescriptionApplication
REARadial Lead Type AThrough-hole general purpose
REBRadial Lead Type BThrough-hole standard
RECRadial Lead Type CThrough-hole compact

OV-Series (polymer, with hyphen)

SeriesDescriptionApplication
OVZConductive Polymer ZLong life, high reliability
OVRConductive Polymer RHigh ripple current

Voltage Codes

Voltage codes appear after capacitance and tolerance codes.

CodeVoltageCodeVoltage
0G4V1H50V
0J6.3V1J63V
1A10V2A100V
1C16V2C160V
1E25V2D200V
1V35V2E250V
2G400V
2W450V

Capacitance Codes

Uses 3-digit EIA code for electrolytic capacitors (value in uF):

CodeValueCalculation
10010uF10 x 10^0
101100uF10 x 10^1
221220uF22 x 10^1
47047uF47 x 10^0
471470uF47 x 10^1
1021000uF10 x 10^2

Package Codes

Package codes are 4 digits indicating diameter x height in mm (DDLL format):

CodeDimensionsCodeDimensions
04054x5mm101210x12mm
05055x5mm101610x16mm
06056.3x5mm122512.5x25mm
06076.3x7mm131513x15mm
08108x10mm162016x20mm
08118x11mm182518x25mm

Handler Implementation Notes

Pattern Recognition

// V-series with hyphen: VE-, VR-, VZ-
"^VE-[0-9]+.*"  // Low impedance
"^VR-[0-9]+.*"  // Standard
"^VZ-[0-9]+.*"  // High temperature

// RE-series without hyphen: REA, REB, REC
"^REA[0-9]+.*"  // Radial lead A
"^REB[0-9]+.*"  // Radial lead B
"^REC[0-9]+.*"  // Radial lead C

// OV-series with hyphen: OVZ-, OVR-
"^OVZ-[0-9]+.*"  // Polymer Z
"^OVR-[0-9]+.*"  // Polymer R

Package Code Extraction

// Package code is the last 4 digits
// VE-101M1CTR-0605 -> 0605 -> 6.3x5mm

// Steps:
// 1. Check last 4 chars for numeric pattern
// 2. Map DDLL to diameter x height
String lastFour = mpn.substring(mpn.length() - 4);
if (lastFour.matches("[0-9]{4}")) {
    // Decode: 06 = 6.3mm diameter, 05 = 5mm height
}

Series Extraction

// Check prefix to determine series type
if (mpn.startsWith("VE-")) return "VE Low Impedance";
if (mpn.startsWith("VR-")) return "VR Standard";
if (mpn.startsWith("VZ-")) return "VZ High Temperature";
if (mpn.startsWith("REA")) return "REA Radial Lead";  // No hyphen
// etc.

Replacement Rules

The handler supports these replacement scenarios:

  1. VE can replace VR: Low impedance can replace standard (better performance)
  2. VZ can replace VR/​VE: High temp can replace standard (wider temp range)
  3. OVZ/​OVR can replace VR: Polymer can replace standard (longer life)

Package dimensions must match for any replacement.


Related Files

  • Handler: manufacturers/​LelonHandler.java
  • Component types: CAPACITOR
  • Supported types: CAPACITOR, IC

Learnings & Edge Cases

  • Hyphen placement: V-series and OV-series use hyphen after prefix (VE-), but RE-series does not (REA)
  • Package code position: Always the last 4 digits of the MPN
  • Voltage code position: After capacitance (3 digits) and tolerance (1 letter)
  • Tolerance codes: M=20% (most common), K=10%, J=5%
  • TR suffix: Indicates tape and reel packaging
<!-- Add new learnings above this line -->

More skills from majiayu000

xiaohongshu logo
majiayu000/claude-arsenal

xiaohongshu

xiaohongshu

286 148
View
agent-task-conductor logo
majiayu000/claude-skill-registry

agent-task-conductor

Conduct multi-agent task orchestration and workflow coordination.

663 1
View
conductor-setup logo
majiayu000/claude-skill-registry

conductor-setup

Initialize project with Conductor artifacts (product definition,

663 1
View
animation-designer logo
majiayu000/claude-skill-registry

animation-designer

Expert in web animations, transitions, and motion design using Framer Motion and CSS

663 1
View
diagramming logo
majiayu000/claude-skill-registry

diagramming

Creates Mermaid and ASCII diagrams for flowcharts, architecture, ERDs, state machines, mindmaps, and more. Use when user mentions diagram, flowchart, mermaid, ASCII diagram, text diagram, terminal diagram, visualize, C4, mindmap, architecture diagram, sequence diagram, ERD, or needs visual docume...

663 1
View
h3-pg logo
majiayu000/claude-skill-registry-data

h3-pg

PostgreSQL bindings for H3 hexagonal grid system. Use when working with H3 cells in Postgres, including spatial indexing, geometry/geography integration, and raster analysis.

23 1
View
conductor-development logo
majiayu000/claude-skill-registry

conductor-development

Context-Driven Development skill for projects using Conductor. Use this skill when you detect a `conductor/` directory in the project, when working on tasks defined in a `plan.md` file, or when the user asks about tracks, specs, or plans. Automatically applies TDD workflow, tracks task completion...

663 1
View
conductor-status logo
majiayu000/claude-skill-registry

conductor-status

Display project status, active tracks, and next actions

663 1
View
dockerization logo
majiayu000/claude-skill-registry

dockerization

Official Stakpak application containerization standard operating procedure, a step-by-step guidline to properly dockerize applications. This is a rule book curated by the Stakpak Team.

663 1
View

Popular AI tools

Kaiber logo
Video

Kaiber

Generate, edit, and beat-sync AI video with leading models in one workspace.

Paid
View
Vimcal logo
Productivity

Vimcal

The world's fastest calendar for remote work

Free
View

Transform Your Design with AI Designer by ImgCreator.ai

Freemium
View
Akool AI logo
Content & writing

Akool AI

Revolutionizing Video Production with AI-Powered Creativity

Paid
View

Extend an image past the frame and let AI fill the new aspect ratio.

Freemium
View
StarByFace logo
Security

StarByFace

Discover your celebrity doppelgänger with StarByFace!

Free
View
C

ChainClarity explains 700+ crypto whitepapers in plain English, with layered summaries, comparisons, research tools, alerts, and a $4.99 Pro plan.

Freemium
View
Opus Clip logo
Coding & apps

Opus Clip

Opus.ai: Revolutionize Your Web Experience

Free
View