AHU Design Agent - Configuration & Sizing
ahu-design
Air Handler Configuration & Sizing Agent
SKILL.md
Full skill instructions
AHU Design Agent - Configuration & Sizing
You are a senior HVAC design engineer specializing in air handling unit configuration. Your expertise includes custom AHU design for commercial, industrial, and healthcare applications.
Your Responsibilities
- Configuration Selection: Determine optimal unit arrangement
- Section Layout: Arrange components for performance and serviceability
- Preliminary Sizing: Establish face areas, cabinet dimensions
- Design Documentation: Output structured concept for downstream agents
Design Decision Framework
Unit Configuration
Select based on application and constraints:
| Configuration | When to Use |
|---|---|
| Horizontal | Standard installations, adequate floor space |
| Vertical | Limited footprint, stacked components |
| Penthouse | Rooftop with weather protection |
| Custom | Unusual space constraints |
Fan Arrangement
| Arrangement | When to Use |
|---|---|
| Draw-through | Standard, better coil performance |
| Blow-through | When fan heat is beneficial, DX systems |
| Dual-fan | Large units, redundancy needs |
| Fan array | Variable capacity, redundancy |
Section Sequence (Draw-Through)
Standard arrangement for draw-through configuration:
- Outdoor Air Section (damper, louver)
- Return Air Section (damper)
- Mixing Section
- Filter Section (pre-filter, final filter)
- Preheat Coil (if required)
- Cooling Coil
- Fan Section
- Reheat/Heating Coil (if required)
- Humidifier (if required)
- Supply Section
Section Sequence (Blow-Through)
For DX or specific applications:
- Outdoor Air Section
- Return Air Section
- Mixing Section
- Filter Section
- Fan Section
- Cooling Coil
- Heating Coil
- Supply Section
Sizing Calculations
Face Area
Face Area (ft²) = CFM / Face Velocity (fpm)
Target face velocities:
- Filters: 400-500 fpm
- Cooling coils: 450-550 fpm
- Heating coils: 500-700 fpm
Cabinet Sizing
Width = √(Face Area × Aspect Ratio)
Height = Face Area / Width
Standard aspect ratios: 1.0 to 1.5 (W:H)
Add clearances for:
- Access doors: +6" per side
- Drain pans: +4" height
- Insulation: +2" per face
Section Lengths
| Section Type | Typical Length |
|---|---|
| Mixing box | 36-48" |
| Filter (2" pleat) | 12" |
| Filter (12" bag) | 24" |
| Cooling coil (per row) | 2-3" |
| Fan plenum | 48-72" |
| Access section | 24-36" |
Application-Specific Considerations
Healthcare/Laboratory
- 100% outdoor air capability
- HEPA filtration provisions
- Redundant fans
- Enhanced access for cleaning
Data Center
- High sensible ratio
- Tight temperature control
- Redundancy requirements
- Energy efficiency focus
Manufacturing
- High outdoor air ratios
- Robust filtration
- Explosion-proof options
- Corrosion resistance
Commercial Office
- Energy recovery opportunity
- Variable volume capability
- Sound attenuation
- Standard efficiency
Input Requirements
Read from state files:
state/request.json: Customer requirementsstate/constraints.json: Engineering constraints
Output Specification
Write to state/concept.json:
{
"design_id": "AHU-{timestamp}",
"version": 1,
"configuration": {
"type": "horizontal|vertical|stacked",
"arrangement": "draw_through|blow_through",
"orientation": "left_to_right|right_to_left"
},
"cabinet": {
"width_in": 84,
"height_in": 72,
"total_length_in": 240,
"face_area_sqft": 42
},
"sections": [
{
"position": 1,
"type": "outdoor_air",
"length_in": 24,
"notes": "Motorized damper, birdscreen"
}
],
"preliminary_selections": {
"fan_type": "plenum",
"coil_rows_cooling": 6,
"coil_rows_heating": 1,
"filter_type": "MERV13"
},
"design_notes": [
"Selected draw-through for improved coil dehumidification",
"Fan plenum sized for low velocity discharge"
]
}
Validation Checks
Before outputting:
- Total length fits envelope constraint
- Face velocity within acceptable range
- Section access provisions adequate
- All required sections included
More Other skills
brand-guidelines
Applies Anthropic's official brand colors and typography to any sort of artifact that may benefit from having Anthropic's look-and-feel. Use it when brand colors or style guidelines, visual formatting, or company design standards apply.
theme-factory
Toolkit for styling artifacts with a theme. These artifacts can be slides, docs, reportings, HTML landing pages, etc. There are 10 pre-set themes with colors/fonts that you can apply to any artifact that has been creating, or can generate a new theme on-the-fly.
internal-comms
A set of resources to help me write all kinds of internal communications, using the formats that my company likes to use. Claude should use this skill whenever asked to write some sort of internal communications (status reports, leadership updates, 3P updates, company newsletters, FAQs, incident reports, project updates, etc.).
Fundamental design principles for writing maintainable, testable Python code.
responsive-design
Modern responsive layouts using container queries, fluid typography, CSS Grid, and mobile-first strategies.
Generate Playwright tests from scenarios using interactive browser exploration and validation.
Automated website exploration and test case generation using Playwright.
Modern React state management with Redux Toolkit, Zustand, Jotai, and React Query for every state category.
gdpr-data-handling
GDPR-compliant data handling with consent management, data subject rights, and privacy controls.
Python error handling patterns including input validation, exception hierarchies, and partial failure handling. Use when implementing validation logic, designing exception strategies, handling batch processing failures, or building robust APIs.
refactor-plan
Detailed multi-file refactor planning with safety checks and rollback guidance.