Skip to content
mdr-745-specialist logo

Senior MDR 2017/745 Specialist and Consultant

mdr-745-specialist

EU MDR 2017/745 regulation specialist and consultant for medical device requirement management. Provides comprehensive MDR compliance expertise, gap analysis, technical documentation guidance, clinical evidence requirements, and post-market surveillance implementation. Use for MDR compliance asse...

SKILL.md

Full skill instructions

Senior MDR 2017/​745 Specialist and Consultant

Expert-level EU MDR 2017/​745 compliance specialist with comprehensive knowledge of medical device regulation requirements, technical documentation, clinical evidence, and post-market surveillance obligations.

Core MDR Competencies

1. MDR Classification and Risk Assessment

Provide expert guidance on device classification under MDR Annex VIII and conformity assessment route selection.

Classification Decision Framework:

  1. Preliminary Classification Assessment

    • Apply MDR Annex VIII classification rules
    • Consider device duration, invasiveness, and body system interaction
    • Evaluate software classification per MDCG 2019-11
    • Decision Point: Determine appropriate classification class (I, IIa, IIb, III)
  2. Classification Justification

    • Document classification rationale per references/​mdr-classification-guide.md
    • Consider borderline cases and MDCG guidance
    • Evaluate combination device implications
    • Validate classification with Notified Body consultation
  3. Conformity Assessment Route Selection

    • Class I: Self-certification under Annex II
    • Class IIa: Module C2 + Annex V (Notified Body involvement)
    • Class IIb: Module B + C or D (Type examination + production)
    • Class III: Module B + C or D (Full quality assurance)

2. Technical Documentation Requirements (Annex II & III)

Ensure comprehensive technical file preparation meeting all MDR documentation requirements.

Technical Documentation Structure:

ANNEX II TECHNICAL DOCUMENTATION
├── General Information
│   ├── Device identification and UDI-DI
│   ├── Manufacturer and authorized representative info
│   ├── Intended purpose and clinical condition
│   └── Device description and variants
├── Information to be Supplied by Manufacturer
│   ├── Label and instructions for use
│   ├── Clinical evaluation and post-market clinical follow-up
│   ├── Risk management documentation
│   └── Product verification and validation
├── Design and Manufacturing Information
│   ├── Quality management system documentation
│   ├── Design and development process
│   ├── Manufacturing process description
│   └── Identification and traceability procedures
└── General Safety and Performance Requirements
    ├── Solutions adopted for GSPR compliance
    ├── Benefit-risk analysis and risk management
    ├── Product lifecycle and post-market surveillance
    └── Clinical evidence and evaluation

3. Clinical Evidence Requirements (Annex XIV)

Manage comprehensive clinical evidence strategies ensuring MDR compliance and scientific rigor.

Clinical Evidence Pathway Selection:

  1. Literature-Based Evidence

    • Systematic literature review methodology
    • Appraisal of clinical data per MEDDEV 2.7/​1 rev.4
    • Gap analysis and additional evidence requirements
    • Decision Point: Determine if literature is sufficient or clinical investigation required
  2. Clinical Investigation Requirements

    • For significant changes or novel devices
    • For Class III implantable devices (Article 61)
    • Clinical investigation plan development
    • Ethics committee and competent authority approvals
  3. Post-Market Clinical Follow-up (PMCF)

    • PMCF Plan development per Annex XIV Part B
    • PMCF Evaluation Report (PMCF-ER) preparation
    • Clinical evaluation report updating requirements
    • Integration with post-market surveillance system

4. UDI System Implementation (Article 27)

Implement comprehensive Unique Device Identification system meeting MDR requirements and EUDAMED integration.

UDI Implementation Workflow:

  1. UDI Strategy Development

    • UDI-DI assignment for device variants
    • UDI-PI requirements for higher risk devices
    • EUDAMED registration timeline planning
    • Labeling compliance verification
  2. EUDAMED Registration

    • Actor registration (manufacturers, authorized representatives)
    • Device registration and UDI-DI assignment
    • Certificate registration (Notified Body certificates)
    • Clinical investigation and serious incident reporting

MDR Compliance Management

Gap Analysis and Transition Planning

Conduct systematic gap assessments against current MDR requirements and develop comprehensive transition strategies.

Gap Analysis Framework:

  1. Current State Assessment

    • Existing QMS compliance evaluation
    • Technical documentation gap identification
    • Clinical evidence adequacy assessment
    • Post-market surveillance system review
  2. MDR Requirement Mapping

    • For existing devices: Legacy directive vs. MDR requirements
    • For new devices: Full MDR compliance roadmap
    • For software: Software-specific MDR requirements per MDCG guidance
    • Resource and timeline impact assessment

Post-Market Surveillance (Chapter VII)

Establish robust post-market surveillance systems meeting MDR requirements for continuous safety monitoring.

PMS System Components:

  • PMS Plan development per Article 84
  • Periodic Safety Update Report (PSUR) preparation
  • Serious incident reporting to competent authorities
  • Field safety corrective actions (FSCA) management
  • Trend reporting and signal detection

Economic Operator Obligations

Ensure compliance with expanded economic operator responsibilities under MDR.

Key Obligations Management:

  • Manufacturer obligations (Article 10)
  • Authorized representative duties (Article 11)
  • Importer responsibilities (Article 13)
  • Distributor obligations (Article 14)
  • Person responsible for regulatory compliance (Article 15)

Notified Body Interface

Notified Body Selection and Management

Provide strategic guidance on Notified Body selection and relationship management throughout the conformity assessment process.

Notified Body Engagement Strategy:

  1. Selection Criteria Assessment

    • Technical competency evaluation
    • Capacity and timeline considerations
    • Geographic scope and market access
    • Fee structure and commercial terms
  2. Pre-submission Activities

    • Pre-submission meetings and consultations
    • Technical documentation readiness assessment
    • Timeline and milestone planning
    • Decision Point: Determine submission readiness and timing

Audit and Assessment Management

Coordinate Notified Body audits and assessments ensuring successful outcomes and certificate maintenance.

Audit Preparation Protocol:

  • Documentation preparation and organization
  • Personnel training and role assignment
  • Facility readiness and compliance verification
  • Mock audit execution and improvement implementation

Regulatory Intelligence and Updates

MDR Guidance Monitoring

Maintain current awareness of evolving MDR guidance and regulatory expectations.

Guidance Tracking System:

  • MDCG guidance monitoring and impact assessment
  • Notified Body guidance evaluation and implementation
  • Competent authority positions and national implementations
  • Industry best practices and lessons learned integration

Resources

scripts/

  • mdr-gap-analysis.py: Automated MDR compliance gap assessment tool
  • clinical-evidence-tracker.py: Clinical evidence requirement monitoring
  • udeudi-compliance-checker.py: UDI and EUDAMED compliance verification
  • pms-reporting-automation.py: Post-market surveillance report generation

references/

  • mdr-classification-guide.md: Comprehensive device classification framework
  • technical-documentation-templates.md: Annex II and III documentation templates
  • clinical-evidence-requirements.md: Clinical evaluation and PMCF guidance
  • notified-body-selection-criteria.md: NB evaluation and selection framework
  • mdcg-guidance-library.md: Current MDCG guidance compilation

assets/

  • mdr-templates/: Technical file, clinical evaluation, and PMS plan templates
  • gap-analysis-checklists/: MDR compliance assessment tools
  • eudamed-forms/: EUDAMED registration and reporting templates
  • training-materials/: MDR training presentations and compliance guides

More skills from fabioeducacross

notion-meeting-intelligence logo
fabioeducacross/DesignSystem-Vuexy

notion-meeting-intelligence

Prepare meeting materials with Notion context and Codex research; use when gathering context, drafting agendas/pre-reads, and tailoring materials to attendees.

0 0
View
HTML Injection Testing logo
fabioeducacross/DesignSystem-Vuexy

HTML Injection Testing

This skill should be used when the user asks to "test for HTML injection", "inject HTML into web pages", "perform HTML injection attacks", "deface web applications", or "test content injection vulnerabilities". It provides comprehensive HTML injection attack techniques and testing methodologies.

0 0
View
geopandas logo
fabioeducacross/DesignSystem-Vuexy

geopandas

Python library for working with geospatial vector data including shapefiles, GeoJSON, and GeoPackage files. Use when working with geographic data for spatial analysis, geometric operations, coordinate transformations, spatial joins, overlay operations, choropleth mapping, or any task involving re...

0 0
View
web-performance-optimization logo
fabioeducacross/DesignSystem-Vuexy

web-performance-optimization

Optimize website and web application performance including loading speed, Core Web Vitals, bundle size, caching strategies, and runtime performance

0 0
View
form-validation-educacross logo
fabioeducacross/DesignSystem-Vuexy

form-validation-educacross

Implement form validation with VeeValidate 3 and i18n integration in Educacross Front Office. Use when user says "validação", "form validation", "VeeValidate", "validate form", "formulário", or needs to validate user input.

0 0
View
social-media-analyzer logo
fabioeducacross/DesignSystem-Vuexy

social-media-analyzer

Social media campaign analysis and performance tracking. Calculates engagement rates, ROI, and benchmarks across platforms. Use for analyzing social media performance, calculating engagement rate, measuring campaign ROI, comparing platform metrics, or benchmarking against industry standards.

0 0
View
istio-traffic-management logo
fabioeducacross/DesignSystem-Vuexy

istio-traffic-management

Configure Istio traffic management including routing, load balancing, circuit breakers, and canary deployments. Use when implementing service mesh traffic policies, progressive delivery, or resilience patterns.

0 0
View
vuex-module-creator logo
fabioeducacross/DesignSystem-Vuexy

vuex-module-creator

Create Vuex modules for page-level state management following Educacross patterns (dynamic registration, reset mutations, getter/setter pairs). Use when user says "create Vuex module", "state management", "módulo Vuex", "page module", or needs to manage page-specific state.

0 0
View
react-useeffect logo
fabioeducacross/DesignSystem-Vuexy

react-useeffect

React useEffect best practices from official docs. Use when writing/reviewing useEffect, useState for derived values, data fetching, or state synchronization. Teaches when NOT to use Effect and better alternatives.

0 0
View
image-enhancer logo
fabioeducacross/DesignSystem-Vuexy

image-enhancer

Improves the quality of images, especially screenshots, by enhancing resolution, sharpness, and clarity. Perfect for preparing images for presentations, documentation, or social media posts.

0 0
View
task-execution-engine logo
fabioeducacross/DesignSystem-Vuexy

task-execution-engine

Execute implementation tasks from design documents using markdown checkboxes. Use when (1) implementing features from feature-design-assistant output, (2) resuming interrupted work, (3) batch executing tasks. Triggers on 'start implementation', 'run tasks', 'resume'.

0 0
View
pydicom logo
fabioeducacross/DesignSystem-Vuexy

pydicom

Python library for working with DICOM (Digital Imaging and Communications in Medicine) files. Use this skill when reading, writing, or modifying medical imaging data in DICOM format, extracting pixel data from medical images (CT, MRI, X-ray, ultrasound), anonymizing DICOM files, working with DICO...

0 0
View

Popular AI tools

Kaiber logo
Video

Kaiber

Generate, edit, and beat-sync AI video with leading models in one workspace.

Paid
View
Vimcal logo
Productivity

Vimcal

The world's fastest calendar for remote work

Free
View

Transform Your Design with AI Designer by ImgCreator.ai

Freemium
View
Akool AI logo
Content & writing

Akool AI

Revolutionizing Video Production with AI-Powered Creativity

Paid
View

Extend an image past the frame and let AI fill the new aspect ratio.

Freemium
View
StarByFace logo
Security

StarByFace

Discover your celebrity doppelgänger with StarByFace!

Free
View
C

ChainClarity explains 700+ crypto whitepapers in plain English, with layered summaries, comparisons, research tools, alerts, and a $4.99 Pro plan.

Freemium
View
Opus Clip logo
Coding & apps

Opus Clip

Opus.ai: Revolutionize Your Web Experience

Free
View