timlawrenz/dinox-ct-msd-hepatic-vessel-vit-base-v1
dinox-ct-msd-hepatic-vessel-vit-base-v1 is a image classification model from timlawrenz. Use it when you need a label for an image. It is set up for dinox-zoo. The card lists the license as apache-2.0.
Scale-aware ViT-Base (86M) organ-specialist for hepatic / portal vessel tissue detection in abdominal CT, self-supervised on MSD Hepatic-Vessel, LoRA fine-tuned for slice-level vessel-present classification.
Downloads · 30 days
8
19% of all-time downloads
All-time downloads
43
Public
Repo size
1 GB
Likes
1
Public
Click a slice to open those files.
.safetensors692 MB · 67%
From the Hugging Face model README
Scale-aware ViT-Base (86M) organ-specialist for hepatic / portal vessel tissue detection in abdominal CT, self-supervised on MSD Hepatic-Vessel, LoRA fine-tuned for slice-level vessel-present classification.
Research use only. Not a clinical diagnostic device.
| Architecture | Scale-aware ViT-Base (dim 768, depth 12, patch 14) |
| Pretraining | DINO self-supervised, single-organ MSD Hepatic-Vessel, 50K steps |
| Fine-tuning | LoRA (rank 8, alpha 16) on vessel-present binary labels |
| Internal AUROC | 0.9456 (leakage-caveated, not release-supporting) |
| External slice AUROC (TCIA CRLM) | 0.9413 slice-level, 17,639 slices / 197 patients |
| External Spearman (vessel-fraction vs score) | r_s = 0.527, p ≈ 1.8e-15 |
| Input | hu16_png 16-bit HU slices, windowing level −30 / width 120, 224px |
| License | Apache-2.0 |
Why slice-level, not patient-level, is the headline: the external set has 196 vessel-positive patients and only 1 all-negative patient, so a patient-level ROC-AUC would be computed against a single negative — statistically degenerate. We therefore do not report a patient-level AUROC as a metric; the defensible generalization metrics are the slice-level AUROC (0.9413) and the Spearman rank correlation (0.527), both robust to the class split. (The ill-posed patient task is documented in
the_science/03_validation.md.)
The primary value of this release is the pretrained scale-aware backbone for downstream tasks (feature extraction, fine-tuning to segmentation/regression). The shipped vessel-present classifier is a proof-of-representation artifact demonstrating the backbone encodes real vessel-tissue signal (external slice AUROC 0.9413). Not for diagnosis or treatment planning.
⚠️ Compatibility: this model uses a custom scale-aware architecture and is served through the
zooinference package (library_name: dinox-zoo). It cannot be loaded with standardtransformers.AutoModel/AutoModelForImageClassification— there is no unifiedmodel.safetensorsandtransformersdoes not implement theScaleEmbeddingspacing logic. Use thezoopath below.
The release ships as weights-only — the inference harness is the open-source
zoo package. This card's numbers were
produced by exactly this path.
Get P(vessel-present) for a CT slice in one call. Preprocessing (the trained
−30/120 HU window, resize, ImageNet norm, spacing) is baked in and cannot
diverge from the validated pipeline:
from zoo.predict import load_classifier, predict_proba
clf = load_classifier("timlawrenz/dinox-ct-msd-hepatic-vessel-vit-base-v1")
p = predict_proba(clf, hu_slice, pixel_spacing=(0.77, 0.77), slice_thickness=1.5)
print(p) # P(vessel present) in [0, 1]
hu_slice is a single (H, W) numpy array in Hounsfield Units (e.g. a DICOM after
rescale slope/intercept). predict_proba internally replicates it to the backbone's 3
input channels — the released classifier path is single-slice (the channel dim is a
copy). We measured the cost of this directly on the external set: true 3-slice context
[z−1,z,z+1] scored AUROC 0.94113 vs the duplicated single slice 0.94130 (Δ = −0.0002,
17,639 slices) — collapsing the z-axis costs nothing measurable here. If you load the
backbone alone for a multi-slice downstream task, pass 3 genuine adjacent slices.
Output is a raw softmax probability — this model ships without calibration or uncertainty (see Limitations).
git clone https://github.com/timlawrenz/DINO-X.git
cd DINO-X
python -m venv .venv && source .venv/bin/activate
# 1) torch for your hardware (CPU/CUDA default; see pytorch.org for CUDA/ROCm)
pip install torch torchvision
# 2) inference deps + the zoo package
pip install -r requirements-inference.txt
pip install . # makes `from zoo.predict import ...` importable
The model is device-agnostic and runs on CPU, CUDA, or ROCm.
requirements-inference.txthas no machine-specific pins; the training repo'srequirements.txtis only needed for the training hosts.
load_classifier does for you)You don't need this to use the model — it's here so the load is transparent. The
release ships a merged backbone (backbone_merged.safetensors — the LoRA adapter
folded into the base weights at release time), so inference needs no peft and the
LoRA double-wrap footgun is structurally impossible:
# (a) merged scale-aware ViT-Base backbone (config.json + backbone_merged.safetensors)
# (c) task head (nn.Linear 768 -> 2) loaded from head.pth
(The unmerged backbone.safetensors + adapter_model.safetensors remain in the repo
for provenance; load_classifier prefers the merged file and only falls back to the
adapter if the merged file is absent. If you use the unmerged path directly, do not
call apply_lora() on top of load_adapter — that double-wraps the backbone.)
It reads the trained HU window and num_classes from finetune_config.json so
preprocessing always matches training.
The backbone is scale-aware: it ingests (spacing_x, spacing_y, slice_thickness) from
your DICOM header through a ScaleEmbedding MLP. The training spacing manifold
(from data_catalog.md) was:
spacing_x/y: 0.57–0.98 mm (mean 0.80)slice_thickness: 0.8–8.0 mm (mean 3.28)Inputs within that range are handled smoothly; inputs outside it (e.g. spacing 1.5 mm, or a 0.5 mm high-resolution slice) are out-of-distribution for the scale embedding — the model still returns a value, but correctness is not validated there. Pass the true DICOM spacing; do not assume it interpolates arbitrary scales.
The external eval's vessel_labels.csv points at hu16_png files. To regenerate them
from raw TCIA CRLM DICOMs, use the repo's preprocessing script
(scripts/preprocessing/phase2_preprocess_nifti.py for NIfTI, or the CRLM label
extractor scripts/preprocessing/extract_crlm_vessel_labels.py that maps SEG → per-slice
labels over the CT). The canonical encoding is u16 = round(HU*10) + 32768 (see
docs/DATA_SOURCES.md). Without this step, reproduce/repro_metrics.py cannot run —
this is the documented v1 caveat (full public repro lands in v1.1 once CRLM licensing
is resolved).
For a list of slices, call predict_proba per slice (or zoo.encode.encode_batch
for backbone features). The external-eval label rows look like:
{'png_path': '...', 'spacing_x': 0.77, 'spacing_y': 0.77, 'spacing_z': 1.5, 'label': 1}
For 16-bit PNG inputs (the training input_format), pass
input_format="hu16_png" to predict_proba. The stored 16-bit encoding is
uint16 = round(HU * 10) + 32768 (one decimal of HU precision, HU range
≈ [−3276.8, +3276.7]); the decode is HU = (uint16 − 32768) * 0.1. This is the
encoding of the shipped training/eval PNGs — verified against the on-disk bytes.
The hu_float and hu16_png paths agree to within float rounding.
Re-run the external evaluation on TCIA CRLM with the exact reproduction harness to confirm you can reproduce the headline number before trusting your own run:
python scripts/eval_external.py \
--adapter path/to/dinox-ct-msd-hepatic-vessel-vit-base-v1 \
--label-csv data/crlm/vessel_labels.csv \
--window-level -30 --window-width 120 --device cuda
Data access: the CRLM evaluation set is derived from TCIA ColoRectal Liver Metastases and is not bundled with this release in v1 (licensing review in progress). The reproduction commands above require obtaining CRLM from TCIA. A small bundled demo sample for verifying the inference mechanics ships in v1 — see
reproduce/README.md.
See reproduce/README.md for the full reproduction recipe and reproduce/repro_metrics.py.
This model ships with a full evidence envelope — every number is traceable to an experiment, every failure is published, and the headline number reproduces mechanically:
the_science/01_decision_trail.mdthe_science/02_training_recipe.mdthe_science/03_validation.mdthe_science/04_negative_results.mdthe_science/05_known_limits.mdreproduce/README.md + reproduce/repro_metrics.pyWe do not ask you to trust our AUROC. We give you the pan-organ failure, the record of us catching our own leakage, and a script to recompute the external number.
If you use this model, please cite the model, the training dataset (MSD Hepatic Vessel), and the external validation dataset (TCIA CRLM):
This model
@misc{lawrenz2026dinox_hepatic_vessel_v1,
title = {dinox-ct-msd-hepatic-vessel-vit-base-v1: Scale-aware ViT-Base specialist
for hepatic vessel detection in abdominal CT (DINO-X model zoo)},
author = {Lawrenz, Tim},
year = {2026},
howpublished = {\url{https://huggingface.co/timlawrenz/dinox-ct-msd-hepatic-vessel-vit-base-v1}},
note = {Release with evidence envelope: external AUROC 0.9413 (TCIA CRLM, 197 patients)}
}
Training data — Medical Segmentation Decathlon (Task 08: Hepatic Vessels)
@article{antonelli2022msd,
title = {The Medical Segmentation Decathlon},
author = {Antonelli, Michela and Reinke, Annika and Bakas, Spyridon and Farahani, Keyvan
and Kopp-Schneider, Annette and Landman, Bennett A. and Litjens, Geert and
Menze, Bjoern and Ronneberger, Olaf and Summers, Ronald M. and others},
journal = {Nature Communications},
year = {2022},
volume = {13},
pages = {4128},
doi = {10.1038/s41467-022-30695-9},
note = {arXiv:2106.05735}
}
External validation data — TCIA Colorectal-Liver-Metastases
@misc{simpson2023crlm,
title = {Preoperative CT and Survival Data for Patients Undergoing Resection of
Colorectal Liver Metastases (Colorectal-Liver-Metastases) (Version 2) [Data set]},
author = {Simpson, Amber L. and Peoples, Jacob and Creasy, John M. and Fichtinger, Gabor
and Gangai, Natalie and Lasso, Andras and Keshava Murthy, Keshava N. and
Shia, Jinru and D'Angelica, Michael I. and Do, Richard K. G.},
year = {2023},
publisher = {The Cancer Imaging Archive},
doi = {10.7937/QXK2-QG03}
}