Downloads · 30 days
8
57% of all-time downloads
szabopeter/joint-segresnet-3d-ex-lidc
joint-segresnet-3d-ex-lidc is a image segmentation model from szabopeter. Use it for the image segmentation task on the model card, and read the license before you ship it in a product. It is set up for pytorch. The card lists the license as apache-2.0.
Single-model, end-to-end 3-class segmentation of chest CT: predicts background / lung / nodule in one forward pass, directly from the full CT (no ROI stage, no bbox crop). Trained on the NLST + NSCLC-Radiomics subset…
Downloads · 30 days
8
57% of all-time downloads
All-time downloads
14
Public
Repo size
82.7 MB
Likes
0
Public
Click a slice to open those files.
.pth82.7 MB · 100%
From the Hugging Face model README
Single-model, end-to-end 3-class segmentation of chest CT: predicts background / lung / nodule in one forward pass, directly from the full CT (no ROI stage, no bbox crop). Trained on the NLST + NSCLC-Radiomics subset of the unified corpus — LIDC-IDRI is excluded because it lacks ground-truth 2D lung labels.
Companion to joint-segresnet-3d-pseudo-lidc (same architecture,
LIDC included via ROI-model-derived pseudo-lung labels), and to
joint-dynunet-3d-{ex,pseudo}-lidc (same task, different architecture).
(1, 256, 256, 256) full CT resampled to 256³ (no bbox crop), intensity-normalised to [0, 1](3, 256, 256, 256) softmax logits — class 0 = background, class 1 = lung, class 2 = noduleNodule is treated as a class distinct from lung: a voxel that is both lung tissue and nodule is assigned exclusively to class 2 (nodule takes precedence over lung).
Trained on the unified_ex_lidc split (patient-grouped,
dataset-stratified, LIDC excluded):
| Source | Role |
|---|---|
| NLST | train + val |
| NSCLC-Radiomics | train + val |
| excluded |
Split sizes: 1 110 train / 196 val / 129 test (held out).
Lung labels are ground-truth per-slice 2D masks (from
roi_sem_seg_2d/), stacked into 3D per series. Nodule labels come from
the corpus's own 3D nodule annotations.
| Class | Dice | Recall | Precision |
|---|---|---|---|
| Lung | 0.9814 | 0.991 | 0.973 |
| Nodule | 0.6546 | 0.650 | 0.659 |
| Combined (mean) | 0.8180 | — | — |
Combined score = 0.5 · (Lung Dice + Nodule Dice). Both class Dices are
per-case-averaged on the val split. Full metric breakdown (mIoU,
Accuracy, per-class Precision/Recall, per-case distribution) is
included as metrics.json alongside this model card once the eval pass
completes.
import yaml, torch
from monai.networks.nets import SegResNet
cfg = yaml.safe_load(open("config.yaml"))["model"]
model = SegResNet(
spatial_dims = cfg["spatial_dims"],
in_channels = cfg["in_channels"],
out_channels = cfg["out_channels"], # 3
init_filters = cfg["init_filters"],
blocks_down = tuple(cfg["blocks_down"]),
blocks_up = tuple(cfg["blocks_up"]),
dropout_prob = cfg["dropout_prob"],
)
state = torch.load("model.pth", map_location="cpu", weights_only=True)
model.load_state_dict(state)
model.eval()
with torch.no_grad():
x = torch.randn(1, 1, 256, 256, 256) # (B, C, H, W, D)
logits = model(x) # (B, 3, D, H, W)
pred_class = logits.argmax(dim=1) # (B, D, H, W) in {0, 1, 2}
lung_mask = (pred_class == 1).to(torch.uint8)
nodule_mask = (pred_class == 2).to(torch.uint8)
Unlike the two-stage nodule-* checkpoints in this collection, this
model does not need a lung-bbox crop — feed it the whole CT
resampled to 256³.
[1.0, 1.0, 100.0] for [bg, lung, nodule])Full config is included in this repo as config.yaml.
The joint task cannot use LIDC directly because LIDC lacks GT lung labels. Two variants were trained:
joint-segresnet-3d-pseudo-lidc: include LIDC with lung labels
produced by the 2D SegResNet ROI model → 1 683 train cases, mixed GT
On the val split, ex-LIDC beats pseudo-LIDC by 0.009 combined Dice (0.8180 vs 0.8087). The pseudo-labels' noise slightly hurts the lung head's supervision signal; the additional LIDC diversity does not compensate. See the companion model card for details.
Model weights released under Apache 2.0. Training data was public but covered by dataset-specific terms (NLST, NSCLC-Radiomics) — users must comply with those separately when using the model on comparable data.
Not a medical device. Not intended for clinical use. Research only.
Paper in preparation.