hxrikp/qwen3-4b-medical-reasoning-qlora
qwen3-4b-medical-reasoning-qlora is a text generation model from hxrikp. Use it when you need the model to write or continue text. It is set up for peft. The card lists the license as apache-2.0.
Title: Qwen3-4B Medical Reasoning (QLoRA) Subtitle: A QLoRA adapter fine-tuning Qwen3-4B-Instruct on medical chain-of-thought reasoning, trained on a single free Kaggle T4 - the SFT checkpoint from the "Confidence Tax…
Downloads · 30 days
16
17% of all-time downloads
All-time downloads
96
Public
Repo size
135 MB
Likes
0
Public
Click a slice to open those files.
.safetensors124 MB · 92%
From the Hugging Face model README
Title: Qwen3-4B Medical Reasoning (QLoRA) Subtitle: A QLoRA adapter fine-tuning Qwen3-4B-Instruct on medical chain-of-thought reasoning, trained on a single free Kaggle T4 - the SFT checkpoint from the "Confidence Tax" study.
Reusable as both the Kaggle model card and the Medium/blog blurb. ⚠️ Research & education only - NOT for clinical or patient-facing use.
A LoRA adapter that fine-tunes Qwen/Qwen3-4B-Instruct-2507
on medical chain-of-thought reasoning. It is the supervised-fine-tuned ("after") checkpoint from a
controlled calibration study of small medical LLMs. The headline finding: this fine-tune makes the
model's internal (token-probability) confidence markedly better calibrated, while its
verbalized (self-reported) confidence does not improve - the two diverge. Trained entirely on a
single free Kaggle T4.
q/v/o/gate/up/down projections. Trainable params well under 1% of the model.train_loss = 1.477 (from ~1.7), grad-norm stable ~0.27, no divergence. ~3.5 h on one T4.adapter_config.json + adapter_model.safetensors). Not a standalone model -
load on top of the base. (Base tokenizer is used; not bundled.)FreedomIntelligence/medical-o1-reasoning-SFT
(Apache-2.0): chain-of-thought medical Q&A, GPT-4o-generated reasoning validated by a medical verifier.
No PHI. ~6,000 examples used.Before (base) vs. after (this adapter) on MedQA + MedMCQA (0-shot, n≈800), with 95% paired bootstrap CIs (2000 resamples). Bold = the change is statistically significant (CI excludes 0).
Internal confidence (max-softmax over option logits - the deployable signal):
| metric | base | +this adapter | Δ [95% CI] |
|---|---|---|---|
| Accuracy ↑ | 0.611 | 0.576 | -0.036 [-0.063, -0.007] |
| ECE ↓ (calibration error) | 0.351 | 0.085 | -0.266 [-0.287, -0.220] |
| AURC ↓ (selective prediction) | 0.223 | 0.236 | +0.013 [-0.013, +0.031] (n.s.) |
| Abstention rate | 0.125 | 0.086 | -0.039 [-0.060, -0.019] |
Verbalized confidence (the "Confidence: NN" it writes after reasoning; unparsed dropped): ECE rises 0.232 to 0.342 (+0.073 [+0.009, +0.130]) - i.e. internal calibration improves while spoken confidence does not. Trust the logits, not the self-report.
Takeaway: internal calibration error roughly quartered (no "confidence tax" in selective prediction), at a small accuracy cost. Replicated on MedGemma-4B (ECE 0.304 to 0.126). Full method, CIs, and the matched-accuracy decomposition: full method, CIs, and code: https://github.com/Mr-Neutr0n/confidence-tax-study
import torch
from transformers import AutoModelForCausalLM, AutoTokenizer
from peft import PeftModel
base = "Qwen/Qwen3-4B-Instruct-2507"
tok = AutoTokenizer.from_pretrained(base)
model = AutoModelForCausalLM.from_pretrained(base, torch_dtype=torch.float16, device_map="auto")