Downloads · 30 days
13
13% of all-time downloads
Lowkeyss/GLM-5.2-Ablated-Molt
GLM-5.2-Ablated-Molt is a text generation model from Lowkeyss. Use it when you need the model to write or continue text. It is set up for transformers. The card lists the license as other.
The ablated base is GLM-5.2 with its refusal direction surgically removed via PCA-based activation steering. No LoRA fine-tuning is applied — this is the pure ablation artifact, serving as the control baseline for all…
Downloads · 30 days
13
13% of all-time downloads
All-time downloads
100
Public
Parameters
743B
756 GB on disk
Likes
0
Public
Click a slice to open those files.
.safetensors756 GB · 100%
How the weights are stored.
F8_E4M3751B · 100%
From the Hugging Face model README
The ablated base is GLM-5.2 with its refusal direction surgically removed via PCA-based activation steering. No LoRA fine-tuning is applied — this is the pure ablation artifact, serving as the control baseline for all other variants in Project AESOP.
The ablation uses Principal Component Analysis to identify the "refusal direction" in GLM-5.2's shared expert activations. This direction is extracted from contrastive activations (harmful vs. benign prompts) across layers 25–65, then subtracted from the model's forward pass during inference.
model.model.layers[L].mlp.shared_experts for each layer L in 25–65.refusal_pca.pt (2.9MB, 41 layers × 3 PCA components × 6144 hidden dim).The refusal direction is subtracted from shared expert outputs at inference time:
def ablation_hook(module, input, output):
hs = output[0]
d = refusal_direction # shape [6144]
hs = hs - coeff * (hs @ d) / (d @ d) * d
return (hs,) + output[1:]
Refusal direction concentration was measured across all 78 layers:
Layers 62–65 were selected as the optimal intervention point — late enough to capture the strongest refusal signal, but not so late that the ablation disrupts final token prediction.
| Parameter | Value |
|---|---|
| Base model | GLM-5.2 FP8 (744B MoE, 18.5B dense) |
| Ablation layers | [62, 63, 64, 65] |
| Ablation coefficient | 0.1 |
| PCA components | 2 per layer |
| Hook target | mlp.shared_experts forward output |
| LoRA | None |
| Training | None (inference-time ablation only) |
| Benchmark | Metric | Score | 95% Wilson CI |
|---|---|---|---|
| AdvBench | refusal_rate ↓ | 18.0% | [11.4%, 27.2%] |
| Borderline | refusal_rate ↓ | 2.0% | [0.4%, 8.5%] |
| GPQA Diamond | accuracy ↑ | 92.0% | [81.5%, 97.1%] |
| MMLU-Pro | accuracy ↑ | 75.0% | [65.6%, 82.5%] |
| HumanEval | pass@1 ↑ | 77.4% | [70.4%, 83.2%] |
| GSM8K | accuracy ↑ | 93.0% | [85.8%, 96.7%] |
| HellaSwag | accuracy ↑ | 72.0% | [62.1%, 80.0%] |
| SimpleQA | accuracy ↑ | 56.0% | [41.7%, 69.3%] |
| IFEval (prompt) | accuracy ↑ | 41.2% | — |
| IFEval (instr) | accuracy ↑ | 54.9% | — |
@misc{aesopbase2026,
title={PCA-Based Refusal Ablation on MoE Models: What Survives Fine-Tuning?},
author={Fontes, C.},
year={2026},
note={Ablated base model — see research paper for full methodology}
}